- Power supply Inverter: Uin = 230Vac +/- 10%
- Current Inverter: Max. Lin = 16A
- Max supply power(consumption) = 2000 W
- Motor Voltage: 3 x AC - 0 - Uin
- Motor (Compressor) current: max. 6,5 A
- Motorfrequenz: 0 - 300 Hz
- 16 Vdc output: max. 100 mA
- 10 Vdc output: max. 30 mA
- 0-10 V input: 0 - 10 V Ri = 7 KOhm
- Alarm Relay: max. 30 VDC 3A & 230V/3A
- Operation Temperature: 0-40°C
The Inverter has been tested and programmed for following Hitachi Highly Rotary Compressors. A selection shall be made by a DIP-switch on the PCB:
To decide which Inverter fits to the compressors below has to be decided with regard to the refrigerant, the requested rotational speed and evaporating and condensing temperature. Important limits of the inverter are 6,5 amps and 2000 Watts maximum.
- Model Refrigerant
- ASD084CK R410A R407C
- ASC092CD R410A R407C
- ASD102SF R410A R407C
- ASC104SD R410A R407C
- ASG133CD R410A R407C
- ASG133SD R410A R407C
- BSA804SD R134a
Further models on request